# Murata LBAD0XX1SC

[**Murata LBAD0XX1SC-DM**](https://www.murata.com/en-us/products/connectivitymodule/lpwa/overview/lineup/type-1sc) The Type 1SC module is the world’s smallest Cat. M1/NB-IoT module with global certification. It supports GPS/GNSS, OpenMCU, and Integrated SIMS.

<figure><img src="/files/AZnpZHgAeStTzlMxBbhb" alt=""><figcaption></figcaption></figure>

### Prerequisites

* Monogoto iSIM profile
* [LBAD0XX1SC-DM](https://www.murata.com/en-us/products/connectivitymodule/lpwa/overview/lineup/type-1sc)

### Quick Navigation

* [Test the connection by sending a PING](#test-the-connection-by-sending-a-ping)
* [Useful Links](#useful-links)

## Connect the LBAD0XX1SC to Monogoto

{% hint style="info" %}
Keep the **AT Commands manual** next to you for more details about the commands. [**Click here**](https://www.murata.com/en-us/products/connectivitymodule/lpwa/overview/lineup/type-1sc) to download the latest version, and scroll down to **Documentation and Resources** to find the AT Commands Manual.
{% endhint %}

#### **Reset the Module**:

Reset non-volatile memory:

Reboot module:

```bash
ATZ
```

**Set the error reporting to verbose**, resulting in more descriptive error messages (optional):

```bash
AT+CMEE=2
```

Check the **status of the SIM card**. The correct response should be: `+CPIN: READY`

```
AT+CPIN?
```

{% hint style="warning" %}
+CPIN: READY means that the iSIM is ready for use and does not require any PIN entry.
{% endhint %}

### Query device information

Request the **product type, hardware,** and **firmware** **version**:

```bash
ATI
```

Request the **IMSI** (International Mobile Subscriber Identity):

```
AT+CIMI
```

Request the **ICCID** (Integrated Circuit Card ID), which is the identification number of the iSIM&#x20;

```
AT%CCID
```

Check the **SIM initialization selection policy** is currently using:

```
AT%GETCFG="SIM_INIT_SELECT_POLICY"
```

Expected response: `SIM_INIT_SELECT_POLICY:5`. The last digit indicates the Active SIM:\
0 indicates **External (SIM card)**\
5 indicates **Internal (iSIM)**

### Network Configuration

It is possible to let the modem select the network automatically or to manually define a network to connect with.

#### **Option 1: Automatic Network Selection**

To set the modem to **automatic network selection** enter the command:

```bash
AT+COPS=0
```

Check the **network and cellular technology the modem** is currently using:

```
AT+COPS? 
```

Expected response: `+COPS: 0,0,"<name of operator>",X`. The last digit indicates the cellular technology:\
7 indicates **LTE Cat-M1**\
8 indicates **NB-IoT**

#### Option 2: Manual Network Selection

Start with searching for available networks:

```
AT+COPS=?
```

{% hint style="warning" %}
It may take several minutes before the modem responds.&#x20;
{% endhint %}

The modem responds with the **names** and the **MCCMNC** codes of the available networks. It also shows the cellular technologies the networks support:&#x20;

```
+COPS: (1,"vodafone NL","voda NL","20404",8),(1,"NL KPN","NL KPN","20408",0),(1,"vodafone NL","voda NL","20404",9),(1,"T-Mobile NL","TMO NL","20416",0),(1,"NL KPN","NL KPN","20408",8),(1,"vodafone NL","voda NL","20404",0),(1,"T-Mobile NL","TMO NL","20416",8),(1,"T-Mobile NL","TMO NL","20416",9),,(0,1,2,3,4),(0,1,2)

OK
```

To find which of the networks Monogoto has **roaming agreements** with, review the [**Coverage lists**](/getting-started/global-public-coverage.md).

{% hint style="info" %}
To find the **profile** of your iSIM, visit the [**Monogoto Console**](https://console.monogoto.io/), open the page **Things** ![](/files/OWVV2DjKOVW5iaNl1NcG) and select a specific **Thing**. Scroll down to **Mobile Identities** to find your profile in the column **Network Provider Name**.

![](/files/0IINqu41pSHJSRJYujvX)
{% endhint %}

Check the **network and cellular technology** the modem is currently using:

```
AT+COPS? 
```

Expected response: `+COPS: 0,0,"<name of operator>",X`. The last digit indicates the cellular technology.

**Manually set the network and the cellular technology**:

```
AT+COPS=1,2,"XXXXX",7
```

Replace `XXXXX` with the **MCCMNC** code of your operator, for example`"20404"` for Vodafone NL. Use `7` for LTE Cat-M1.

**Check the radio signal strength and signal quality:**

```bash
AT+CSQ
```

{% hint style="info" %}
`+CSQ` returns 2 values separated by a comma. The first value represents the **signal strength** and provides a value between 0 and 31; higher numbers indicate better signal strength. The second value represents the **signal quality** indicated by a value between 0 and 7. If `AT+CSQ` returns `99,99`, the signal is undetectable or unknown.
{% endhint %}

#### Define the cellular band(s) (optional)

It is possible to **lock the modem to one or more specific bands**. This may result in a faster boot cycle as the modem does not need to scan for available bands at startup.

{% hint style="info" %}
Support LTE Band: Low Bands 5,8,12,13,14 (CAT M1 Only),17,18,19,20,26,28&#x20;

Mid Bands 1,2,3,4,25
{% endhint %}

{% hint style="warning" %}
Although the modem may support many different bands, your local network operator may not. Have a look at the [**LTE Cat-M1 overview**](broken://pages/GDSRxI85QWE6Z2lsLeS3) to find the available band(s) in your region.
{% endhint %}

To lock the modem to a specific band, a hexadecimal value representing the band needs to be sent to the modem. To **lock the modem to LTE-M band 5**, send:&#x20;

```
AT%SETCFG="BAND","5"
```

{% hint style="info" %}
For information about setting specific LTE bands, see **Murata LBAD0XX1SC-DM** &#x20;

**AT Commands Manual**, chapter **4.2.5.**
{% endhint %}

To test if the band(s) is properly set, enter the command:&#x20;

```
AT%GETCFG="BAND"
```

Example response: Bands: 1 ,2 ,3 ,4 ,5 ,8 ,12 ,13 ,14 ,17 ,18 ,19 ,20 ,25 ,26 ,28\
They represent the LTE-M bands and NB-IoT bands.

#### Query the signal measurement on a cellular network

To information about the technology used, the network provider, and the cellular band, enter:

```
AT%MEAS="8"
```

Example response: `%MEAS:Signal Quality:RSRP= -115,RSRQ= -15,SINR= -3,RSSI= -120.`&#x20;

### Network Activation

**Set the APN to** `go.mono`:

```json
AT+CGDCONT=1,"IP","go.mono"
```

Validate if the **APN** is set correctly:

```
AT+CGDCONT?
```

Expected response: `+CGDCONT: 1,"IP","go.mono","0.0.0.0",0,0,0,0,0,0`

**Activate the PDP (packet data protocol) context**:

```
AT+CGACT=1,1
```

**Test** if the PDP context is activated:

```
AT+CGACT?
```

Expected response: `+CGACT: 1,1`

#### Validate if your device received an **IP address**:

```bash
AT+CGPADDR
```

Expected response: `+CGPADDR: 1,XX.XXX.XX.XXX`

{% hint style="info" %}
Do you see an IP address? **Congratulations! You’ve successfully connected the Murata LBAD0XX1SC-DM modem to Monogoto 🎉**
{% endhint %}

## Test the connection by sending a PING

A PING test can be performed to test if the modem has an active data connection with a mobile network.

{% hint style="warning" %}
When cellular modems are idle for a long period of time, cell towers might drop the data connection to save resources. Sending regular PINGs is a good method for testing the data connection, as well as for keeping the connection alive because the operator registers your device as being actively used.
{% endhint %}

**Send 5 PINGs** to the IP address `8.8.8.8`:

```
AT%PINGCMD=0,"8.8.8.8",5
```

Example response:

```
+QPING: 0,"8.8.8.8",32,543,255
+QPING: 0,"8.8.8.8",32,396,255
+QPING: 0,"8.8.8.8",32,262,255
+QPING: 0,"8.8.8.8",32,299,255
+QPING: 0,4,4,0,262,543,375
```

{% hint style="success" %}
**Great work on connecting the Murata LBAD0XX1SC-DM to Monogoto!** Have a look at the **Things** logs in the [**Monogoto Console**](https://console.monogoto.io/) to find more details about the established connection.
{% endhint %}

## Useful Links

* [QLBAD0XX1SC-DM product page](https://www.murata.com/en-us/products/connectivitymodule/lpwa/overview/lineup/type-1sc#anchor-3)
* [QLBADXX1SC-DM Quick Start Guide](https://3922449203-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2F-M0mPxGpottOEfcucXOR%2Fuploads%2FIQSItX6iyZ35t7a1wnVf%2FLPWA%20Type%201SC%20Quick%20start%20guide_Ver3%201.pdf?alt=media\&token=f8493020-a0a8-4e34-afb8-246540645017)
* [QLBADXX1SC-DM DataSheet](https://wireless.murata.com/pub/RFM/data/lbad0xx1sc.pdf)


---

# Agent Instructions: Querying This Documentation

If you need additional information that is not directly available in this page, you can query the documentation dynamically by asking a question.

Perform an HTTP GET request on the current page URL with the `ask` query parameter:

```
GET https://docs.monogoto.io/getting-started/sim-cards/isim/murata-lbad0xx1sc.md?ask=<question>
```

The question should be specific, self-contained, and written in natural language.
The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.

Use this mechanism when the answer is not explicitly present in the current page, you need clarification or additional context, or you want to retrieve related documentation sections.